BSCBT - CALIBRATION GAS CO 100 PPM IN AIR, 51-1994

  • MSDS: BSCBT
  • Manufacturer: BACHARACH INC
  • Product Name: CALIBRATION GAS CO 100 PPM IN AIR, 51-1994
  • National Stock Number: 6630-00N044542
Product Identification

Product ID:CALIBRATION GAS CO 100 PPM IN AIR, 51-1994
MSDS Date:12/17/1990
FSC:6630
NIIN:00N044542
MSDS Number: BSCBT

Responsible Party
BACHARACH INC
625 ALPHA DR
PITTSBURGH, PA 15238
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 412-963-2223

Cage: 05083

Contractor
BACHARACH INC
PITTSBURGH, PA 15238 US

Telephone: 412-963-2130

Cage: 05083

Ingredients

74%.

CAS: 630-08-0

RTECS: FG3500000

Fraction By Weight: 0.01%

OSHA PEL 35 PPM;200 PPM, C

ACGIH TLV: 25 PPM


AIR

Fraction By Weight: 99.99%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYE/SKIN:NONE KNOWN/EXPECTED.
INHAL:CARBON MONOXIDE IS CHEM ASPHY WHICH AFFECTS OXYGEN TRANSPORT
OF BLOOD. SYMPS INCL HDCH, POUNDING HEART, DIZZ, WEAK, CONFUSN &
NAUS, DEATH MAY RSLT FROM INTENS E/PRLNG EXPOS. INGEST:NOT APPLIC.
THIS MATL IS A GAS. CHRONIC:EXPOS TO LOW LEVELS OF CARBON MONOXIDE
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:MAY ADVERSELY AFFECT CVS. CARBON
MONOXIDE HAS BEEN REPORTED TO CAUSE ADVERSE EFTS ON FERTILITY &
DEVEL ABNORMS & FETAL TOX IN SOME ANIMAL STUDIES. CARBON MONOXIDE
IS MUTAGENIC IN SOME TEST SY S. METHYLENE CHLORIDE IS METABOLIZED
TOCARBON MONOXIDE IN THE BODY & INCREASES TOX EFT OF CARBON
MONOXIDE EXPOSURE.
Medical Cond Aggravated by Exposure:PERSONS W/PRE-EXISTING RESPIRATORY
DISEASE & SMOKERS MAY BE AT INCREASED RISK FROM EXPOSURE.

First Aid

First Aid:INGEST:CALL MD IMMEDIATELY . EYES:IMMEDIATELY FLUSH W/POTABLE
WATER FOR A MINIMUM OF 15 MINUTES, SEEK ASSISTANCE FROM MD .
SKIN:FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD . INHAL:RESC UERS
SHOULD BE AWARE OF HAZARD & WEAR NIOSH/MSHA APPRVD SCBA. REMOVE
VICTIM FROM AREA TO FRESH AIR, GIVE ARTIFICIAL RESPIRATION, GET
IMMEDIATE MEDICAL ATTENTION.

Fire Fighting

Flash Point:NON-FLAMMABLE
Lower Limits:SEE ING 1
Upper Limits:SEE ING 1
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE . THIS GAS IS
NOT FLAMMABLE. COOL EXPOSED CONTAINERS W/WATER.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . USE SHIELDING TO PROTECT FROM CYLINDER EXPLOSION.
Unusual Fire/Explosion Hazard:CONC OF CO IS BELOW LEL SO THIS MIXT IS
NON-FLAMM. COMPRESSED AIR AT HIGH PRESS WILL ACCELERATE BURNING OF
OTHER MATLS. GAS CYLS EXPOS TO HEAT/FLAME MAY(SUPDAT)

Accidental Release

Spill Release Procedures:EVACUATE AREA, WEAR NIOSH/MSHA APPROVED
POSITIVE PRESSURE SCBA & MOVE LEAKING CYLINDER TO A HOOD OF OUTDOOR
LOCATION. ALLOW GAS TO DISSIPATE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE NEAR HEAT/OPEN FLAME.
EXPOS TO TEMPS >125F MAY CAUSE RUPTURE. SECURE CYLS - DO NOT DROP.
OUTDOOR STORAGE PREFERRED. USE ONLY W/ADEQ VENT.
Other Precautions:DO NOT BREATHE GAS. CONTENTS UNDER PRESS. DO NOT
PUNCTURE. NEVER THROW CNTNR INTO FIRE/INCIN. KEEP CYLS SECURED. DO
NOT DROP/DMG. USE PRESS REGULATOR & CHECK VALVES AS APPROP. KEEP
CYLS AWAY FROM HEAT , FLAMES & ALL IGNIT SOURCES. (SUPDAT)

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED POSITIVE PRESSURE SCBA FOR
EMERGENCY USE. DO NOT BREATHE GAS. SELECTION OF RESP PROT DEPENDS
ON CONTAMINANT TYPE, FORM & CONC. SELECT I/A/W OSHA 1910.134 & GOOD
INDUSTRIAL HYGIENE PRACTICE.
Ventilation:LOC EXHST/ADEQ GEN VENT TO MAINTAIN CONC BELOW PEL. SINCE
THIS GAS IS ODORLESS, AREAS OF USE/WHERE CO IS VENTED (SUPDAT)
Protective Gloves:LEATHER GLOVES.
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ:VENT RAPIDLY/EXPLODE. OTHER PREC:ADDNL HNDLG RECS ON
COMPRESSED GAS CYLS, CONSULT COMPRESSED GAS ASSOC PAMPHLET P-1.
PROTECT FROM HEAT & PHYSICAL DMG. VENT:& CO MAY COLLECT SHOULD BE
MONITOR ED TO ASSURE THAT CONCS ARE MAINTAINED BELOW PEL.

Chemical Properties

HCC:G3
Boiling Pt:B.P. Text:-317F,-194C
Vapor Density:1
Spec Gravity:0.8
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS, ODORLESS, TASTELESS COMPRESSED GAS IN
CYLINDERS.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
NONE KNOWN
Stability Condition to Avoid:AVOID HEAT OR FLAMES.
Hazardous Decomposition Products:NONE KNOWN

Disposal

Waste Disposal Methods:DISPOSE I/A/W ALL LOCAL, STATE & FEDERAL
REGULATIONS. DO NOT INCINERATE CYLINDER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.